远端模块固件升级失败。
处理步骤步骤 1中心交换机上查看远端模块的相关告警,是否有与远端模块升级失败相关的告警。RUMNG/2/RUUPGFWFAIL:OID [oid] Theremote-unit firmware upgrade failed. (RemoteUnitEsn=[INTEGER],InterfaceName=[INTEGER], Firmware=[INTEGER], Reason=[STRING])其中Reason=[STRING] 会显示失败信息。告警含义见hwRuMngFirmwareUpdateFail。先根据失败提示信息初步判断。
步骤 2检查远端模块状态和可用的固件版本。执行命令行display remote-unit upgrade information查询当前中心交换机可用固件版本,然后执行命令行display remote-unit verbose查询远端模块固件版本与状态,确认认证等是否正常。
# displayremote-unit upgrade information查询当前中心交换机可用固件版本。
[HUAWEI] display remote-unit upgrade information
Firmware information:
-------------------------------------------------------------------------------
Type Version From Note
-------------------------------------------------------------------------------
APP 220410000 Startup software -
POE 7686 Startup software -
BIOS 220225001 Startup software -
Remote-unit during cooling down:
-------------------------------------------------------------------------------
Type ConnectInterface FailCnt CoolDownInSeconds
-------------------------------------------------------------------------------
Waiting for restart to apply new firmware's remote-unit information:
-------------------------------------------------------------------------------
# displayremote-unit verbose查看远端模块的认证结果,Authen result为Success表示认证成功,其他表示认证不成功,请联系维护确认。
[HUAWEI] display remote-unit verbose
Total number: 1
------------------------------------------------------------------------
ESN :219801176801XXXXXXXX
Name :-
ID :1
Device MAC :XXXX-XXXX-XXXX
Device type :-
Item :-
Manufacture date :-
Up time :0 day, 2 hours, 29 minutes, 52 seconds
APP version :220410000
POE version :-
BIOS version :220225001
Connect interface :MultiGE0/0/5
Disk usage :44%
Memory usage :30%
Temperature :28(°C)
Mac usage :0%
Disk space(MB) :16
Status :Normal
Authen result :Success
------------------------------------------------------------------------
步骤 3检查当前升级的情况,确定当前升级模式和状态。
执行命令行display remote-unit upgrade information查询远端模块升级状态,是否存在失败,等待重启等;如出现失败,执行命令行display remote-unitupgrade record查询远端模块升级记录信息。
# displayremote-unit upgrade information查询远端模块升级状态,Remote-unit during cooling down可以看到是否有升级失败处于冷却期的远端模块。
[HUAWEI] display remote-unit upgrade information
Firmware information:
-------------------------------------------------------------------------------
Type Version From Note
-------------------------------------------------------------------------------
APP 220410000 Startup software -
POE 7686 Startup software -
BIOS 220225001 Startup software -
Remote-unit during cooling down:
-------------------------------------------------------------------------------
Type ConnectInterface FailCnt CoolDownInSeconds
-------------------------------------------------------------------------------
Waiting for restart to apply new firmware's remote-unit information:
-------------------------------------------------------------------------------
Type ConnectInterface NextVersion(APP/POE/BIOS)
-------------------------------------------------------------------------------
Upgrading remote-unit information:
-------------------------------------------------------------------------------
Type ConnectInterface Firmware Percent
-------------------------------------------------------------------------------
MultiGE0/0/5 APP 14%
# displayremote-unit upgrade record查询远端模块升级记录信息。
[HUAWEI] display remote-unit upgrade record
-------------------------------------------------------------------------------
StartTime ConnectInterface Firmware UpdateResult
-------------------------------------------------------------------------------
2022/04/14 2039 MultiGE0/0/5 APP Success
2022/04/14 2057 MultiGE0/0/5 BIOS Success
# 远端模块视图下,执行命令行display this查询是否配置了去使能升级,有upgrade disable回显表示全局去使能升级了,需要使能一下。
[HUAWEI] remote-unit
[HUAWEI-remote-unit] display this
#
remote-unit
upgrade disable
#
return
[HUAWEI] remote-unit 1
[HUAWEI-remote-unit-1] display this
#
remote-unit 1
upgrade disable
bind interface MultiGE0/0/5
#
return
[HUAWEI-remote-unit-1] upgrade enable
步骤 4强制手动升级作为逃生手段。
远端模块视图下,可执行命令行upgrade { app | bios | poe } force强制升级固件。
[HUAWEI-remote-unit] remote-unit 1
[HUAWEI-remote-unit-1] upgrade app force
Info: Successfully added to the upgrade list.
步骤 5请收集日志信息和配置信息,并联系技术支持人员。设备诊断信息可以通过displaydiagnostic-information命令收集。
-