资料介绍
Heart Rate and EKG Monitor using the MSP430FG439:This application report describes how to build a digital heart rate monitor using a MSP430FG439 microcontroller (MCU). The heart beat rate per minute is displayed on a LCD glass. In addition to this the application outputs digital data stream via RS232 serial port to allow EKG waveform display on a PC. PCB Gerber files, schematic, bill of materials and firmware are provided in a zip file associated with this application report.The entire application runs using a CR2032 3-Volt lithium battery.
An electrocardiogram (ECG) also called EKG is a graphic tracing of the voltage generated by the cardiac or heart muscle during a heartbeat. It provides very accurate evaluation of the performance of the heart.The heart generates an electrochemical impulse that spreads out in the heart in such a fashion as to cause the cells to contract and relax in a timely order and thus give the heart a pumping characteristic.This sequence is initiated by a group of nerve cells called the sinoatrial (SA) node resulting in a polarization and depolarization of the cells of the heart. Because this action is electrical in nature and because the body is conductive with its fluid content, this electrochemical action can be measured at the surface of the body.
An actual voltage potential of approximately 1mV develops between various body points. This can be measured by placing electrode contacts on the body. The four extremities and the chest wall have become standard sites for applying the electrodes. Standardizing electrocardiograms makes it possible to compare them as taken from person to person and from time to time from the same person. The normal electrocardiogram shows typical upward and downward deflections that reflect the alternate contraction of the atria (the two upper chambers) and of the ventricles (the two lower chambers) of the heart.A typical single cardiac cycle waveform of a normal heartbeat is shown in Figure 1-1. The voltages produced represent pressures exerted by the heart muscles in one pumping cycle. The first upward deflection, P, is due to atria contraction and is known as the atrial complex. The other deflections, Q, R, S, and T, are all due to the action of the ventricles and are known as the ventricular complexes. Any deviation from the norm in a particular electrocardiogram is indicative of a possible heart disorder.In this application report the EKG waveform is used by the MCU to measure the heart beat rate. Because heart beat calculation is the major focus the electrodes are simplified to two connections one to a right arm and the other to the left arm. This type of set up can be frequently seen in exercise machines such as
a treadmill.
An electrocardiogram (ECG) also called EKG is a graphic tracing of the voltage generated by the cardiac or heart muscle during a heartbeat. It provides very accurate evaluation of the performance of the heart.The heart generates an electrochemical impulse that spreads out in the heart in such a fashion as to cause the cells to contract and relax in a timely order and thus give the heart a pumping characteristic.This sequence is initiated by a group of nerve cells called the sinoatrial (SA) node resulting in a polarization and depolarization of the cells of the heart. Because this action is electrical in nature and because the body is conductive with its fluid content, this electrochemical action can be measured at the surface of the body.
An actual voltage potential of approximately 1mV develops between various body points. This can be measured by placing electrode contacts on the body. The four extremities and the chest wall have become standard sites for applying the electrodes. Standardizing electrocardiograms makes it possible to compare them as taken from person to person and from time to time from the same person. The normal electrocardiogram shows typical upward and downward deflections that reflect the alternate contraction of the atria (the two upper chambers) and of the ventricles (the two lower chambers) of the heart.A typical single cardiac cycle waveform of a normal heartbeat is shown in Figure 1-1. The voltages produced represent pressures exerted by the heart muscles in one pumping cycle. The first upward deflection, P, is due to atria contraction and is known as the atrial complex. The other deflections, Q, R, S, and T, are all due to the action of the ventricles and are known as the ventricular complexes. Any deviation from the norm in a particular electrocardiogram is indicative of a possible heart disorder.In this application report the EKG waveform is used by the MCU to measure the heart beat rate. Because heart beat calculation is the major focus the electrodes are simplified to two connections one to a right arm and the other to the left arm. This type of set up can be frequently seen in exercise machines such as
a treadmill.
下载该资料的人也在下载
下载该资料的人还在阅读
更多 >
- SM2255EKG高功率因数LED线性恒流控制芯片中文手册 0次下载
- process-monitor进程守护者
- WildFly Monitor监控数据发送工具
- 如何使用具有MSP430 USI端口的ADS8361的详细资料概述 13次下载
- Predicting Op Amp Slew Rate Limi 0次下载
- HEART_RATE_PROFILE 0次下载
- Heart-RateFitness Monitors Go Wireless 33次下载
- AVR利用USI模块作为I2C从机 82次下载
- Heart-Rate and EKG Monitor Usi
- Slew Rate of Op Amp Circuits
- Design of Crimp force Monitor
- Serial Monitor (串口监视、检测、分析工具)v
- Implementing Double Data Rate
- DS2155 Monitor Mode Design
- USB Monitor Control Class Spec
- DDR和LPDDR内存技术的相同点和不同点比较 3369次阅读
- 请问运算放大器Slew Rate指标在系统应用中有何意义呢? 808次阅读
- GDDR和DDR代表什么?GDDR和DDR内存有什么区别? 1831次阅读
- $monitor和$strobe有何差异? 511次阅读
- 如何通过GTM Digital monitor读RX Equalizer 520次阅读
- 如何在不提高心率的情况下将心电图添加到您的可穿戴设备中 718次阅读
- FP-AI-MONITOR1简介 1310次阅读
- 在贴片加工厂中有哪些安全防护需要了解 1306次阅读
- 复合放大器实现高精度的高输出驱动能力 获得最佳的性能 1600次阅读
- 东大金智科技Formerica 10G XFP光模块简介英文版 1786次阅读
- 用降压型稳压器或线性稳压器电源时值来会为负载供电 984次阅读
- 串口通信技术简单总结和归纳 9357次阅读
- 全面解读Apollo 3.0 从研发到量产的技术原理 5478次阅读
- 三星推出AR Emoji的另一个原因是——通过实时视频解决带宽问题 5010次阅读
- gps追踪器组成与硬件结构 9784次阅读
下载排行
本周
- 1电子电路原理第七版PDF电子教材免费下载
- 0.00 MB | 1490次下载 | 免费
- 2单片机典型实例介绍
- 18.19 MB | 92次下载 | 1 积分
- 3S7-200PLC编程实例详细资料
- 1.17 MB | 27次下载 | 1 积分
- 4笔记本电脑主板的元件识别和讲解说明
- 4.28 MB | 18次下载 | 4 积分
- 5开关电源原理及各功能电路详解
- 0.38 MB | 10次下载 | 免费
- 6基于AT89C2051/4051单片机编程器的实验
- 0.11 MB | 4次下载 | 免费
- 7蓝牙设备在嵌入式领域的广泛应用
- 0.63 MB | 3次下载 | 免费
- 89天练会电子电路识图
- 5.91 MB | 3次下载 | 免费
本月
- 1OrCAD10.5下载OrCAD10.5中文版软件
- 0.00 MB | 234313次下载 | 免费
- 2PADS 9.0 2009最新版 -下载
- 0.00 MB | 66304次下载 | 免费
- 3protel99下载protel99软件下载(中文版)
- 0.00 MB | 51209次下载 | 免费
- 4LabView 8.0 专业版下载 (3CD完整版)
- 0.00 MB | 51043次下载 | 免费
- 5555集成电路应用800例(新编版)
- 0.00 MB | 33562次下载 | 免费
- 6接口电路图大全
- 未知 | 30320次下载 | 免费
- 7Multisim 10下载Multisim 10 中文版
- 0.00 MB | 28588次下载 | 免费
- 8开关电源设计实例指南
- 未知 | 21539次下载 | 免费
总榜
- 1matlab软件下载入口
- 未知 | 935053次下载 | 免费
- 2protel99se软件下载(可英文版转中文版)
- 78.1 MB | 537791次下载 | 免费
- 3MATLAB 7.1 下载 (含软件介绍)
- 未知 | 420026次下载 | 免费
- 4OrCAD10.5下载OrCAD10.5中文版软件
- 0.00 MB | 234313次下载 | 免费
- 5Altium DXP2002下载入口
- 未知 | 233045次下载 | 免费
- 6电路仿真软件multisim 10.0免费下载
- 340992 | 191183次下载 | 免费
- 7十天学会AVR单片机与C语言视频教程 下载
- 158M | 183277次下载 | 免费
- 8proe5.0野火版下载(中文版免费下载)
- 未知 | 138039次下载 | 免费
评论
查看更多