资料介绍
Abstract
A 2.88nJ/Conversion low energy biopotential acquisition system is designed for portable healthcare device. Two dry copper contact electrodes with 1.2-cm diameter are used to easily interface between skin and healthcare device. Chopping technique is adopted at readout front end to obtain thermal noise floor of 1.3uVrms over 0.5~200Hz and CMRR over 100dB to mitigate common-mode body potential induced from AC power line. A 4-stage gain control and band selection blocks are integrated to digitally calibrate for different types of biomedical signal and an 8-bit synchronous successive approximation register (SAR) A/D is used to digitize sensed biopotentials. A test chip is implemented in 0.18um, 1.8V supply CMOS technology and successively verified by readout ECG signal with two electrodes contact at chest of body with separating 6cm.
I. INTRODUCTION
ECG, EMG and EEG are common biomedical signals that give continuous information for patients undergoing surgery or those admitted to intensive care units (ICUs)。 Conventionally, patients are measured by bulky and mainpowered instrument with several wired leads connected on body which can greatly reduce patient’s mobility and white coat effect in hospital also makes an erroneous diagnosis. Common portable health care approaches which use three Ag/AgCl electrodes with conductive solution provide good signal quality in Skin-Electrode interface [1]。 However, it has the problem of inconvenient patient attachment; also it may cause inflammation of the human skin and limits its reusability and continuous health monitoring. Furthermore, the third reference electrode forms a low impedance node to ground. Hence, patients suffer from hazard of leakage current. Consequently, a low energy, small form factor, two dry electrodes biopotential acquisition system is attractive for ambulatory healthcare application. Previously, several types of commercial metals were investigated as a wearable electrode [2]。 The impedance fluctuation of the different metal electrodes is less than one decade in the frequency range less than 1kHz compared with Ag/AgCl. This indicates that a copper on PCB as an interface between skin and portable instrument can replace the Ag/AgCl electrode without any electrically conductive solution. However, its main drawback is that power line interference problem is severe in twoelectrode recording system [3][4]。 Short distance between two electrodes can reduce electromagnetic interference (EMI) in biopotential measurements since this approach will cause power line 60Hz noise common to readout front end. However, it also suppresses differential signal strength because of the short distance between the electrodes. Moreover, due to the lack of the conductive solution, the skin-electrode interface impedance of dry electrode is much larger than conventional Ag/AgCl electrode which could also degrade signal potential as shown in Fig.1. Therefore, in order to extract biopotenials under such circumstances, the noise and CMRR requirements of analog readout front end are more stringent, while consuming low power. According to [4], only a micro volts noise level is allowed to maintain recorded signal quality at the front end and over 100dB in band CMRR and PSRR of readout front end are also required for robust operation regards to power line interference in such circumstances. Simultaneously, the biopotential acquisition system need to have a programmability for its gain and bandwidth [5] to meet different signal potential and frequency characteristics.
- 便携式医疗监控系统面临的设计挑战
- 便携式心电监护仪采集系统设计
- 高性能便携式医疗设备技术
- 如何使用SOPC实现便携式智能图像采集系统的设计 8次下载
- 基于TMS320VC5505的便携式DSP的医疗应用发展的详细方案分析 9次下载
- 便携式音频播放器的处理器SoC系统软件和电源管理的详细资料概述 5次下载
- 便携式电池系统 10次下载
- 德州仪器多核处理器带来便携式医疗成像系统的创新 8次下载
- 便携式医疗电子系统的组成与片上系统架构的应用 16次下载
- 在便携式医疗设备的心跳 6次下载
- 便携式医疗系统无线监控 6次下载
- 便携式医疗设备新型双电源的实现 89次下载
- 超声便携式设备的系统划分
- 基于ARM的便携式数据采集系统设计
- 基于便携式智能设备的管理系统设计
- 生物电测量前端模拟芯片SC2945在动态心电图中的应用 561次阅读
- AN-1557: AD5940和AD8233在完整生物电系统中的实现 2413次阅读
- 蓝牙低功耗技术在便携式医疗设备中的应用研究 2178次阅读
- 便携式医疗电子设备的应用挑战及解决方案 3264次阅读
- 基于微功耗架构的新型微控制器实现便携式医疗监护系统的设计 2288次阅读
- 便携式医疗系统中无线监控的挑战性要求 2193次阅读
- 便携式医疗设备解析 7772次阅读
- Freescale提供设计便携式导航设备系统解决方案 1242次阅读
- 利用高性能模拟器件简化便携式医疗设备的设计 990次阅读
- 基于ARM与FPGA的便携式GNSS信号采集回放系统设计 1767次阅读
- 便携式设备中的电源效率 1310次阅读
- 一款便携式脑电无线采集系统的设计 1858次阅读
- 专家支招:为何便携式手持医疗设备需要电路保护器件? 2641次阅读
- 采用线阵CCD的便携式光谱采集系统设计 5274次阅读
- 便携式医疗电子设备的无线监测技术 1350次阅读
下载排行
本周
- 1普中科技HC6800-EM3使用操作手册
- 21.69 MB | 3次下载 | 2 积分
- 2PCB板EMC/EMI的设计技巧
- 0.20 MB | 3次下载 | 免费
- 32024PMIC市场洞察
- 2.23 MB | 2次下载 | 免费
- 4MSP430™闪存器件引导加载程序(BSL)
- 1.45MB | 2次下载 | 免费
- 5PL4807单节锂离子电池充电器中文手册
- 1.36 MB | 2次下载 | 免费
- 6LTH7充电电路和锂电池升压5V输出电路原理图
- 0.04 MB | 1次下载 | 免费
- 7HT2120两节锂电池保护板电路
- 0.22 MB | 1次下载 | 免费
- 8BQ77207EVM用户指南
- 865.23KB | 1次下载 | 免费
本月
- 1XL4015+LM358恒压恒流电路图
- 0.38 MB | 148次下载 | 1 积分
- 2PCB布线和布局电路设计规则
- 0.40 MB | 33次下载 | 免费
- 3智能门锁原理图
- 0.39 MB | 13次下载 | 免费
- 4GB/T4706.1-2024 家用和类似用途电器的安全第1部分:通用要求
- 7.43 MB | 11次下载 | 1 积分
- 5JESD79-5C_v1.30-2024 内存技术规范
- 2.71 MB | 10次下载 | 免费
- 6elmo直线电机驱动调试细则
- 4.76 MB | 9次下载 | 6 积分
- 7WIFI智能音箱原理图完整版
- 0.09 MB | 7次下载 | 10 积分
- 8PC1013三合一快充数据线充电芯片介绍
- 1.03 MB | 7次下载 | 免费
总榜
- 1matlab软件下载入口
- 未知 | 935115次下载 | 10 积分
- 2开源硬件-PMP21529.1-4 开关降压/升压双向直流/直流转换器 PCB layout 设计
- 1.48MB | 420061次下载 | 10 积分
- 3Altium DXP2002下载入口
- 未知 | 233084次下载 | 10 积分
- 4电路仿真软件multisim 10.0免费下载
- 340992 | 191367次下载 | 10 积分
- 5十天学会AVR单片机与C语言视频教程 下载
- 158M | 183332次下载 | 10 积分
- 6labview8.5下载
- 未知 | 81581次下载 | 10 积分
- 7Keil工具MDK-Arm免费下载
- 0.02 MB | 73806次下载 | 10 积分
- 8LabVIEW 8.6下载
- 未知 | 65985次下载 | 10 积分
评论
查看更多