资料介绍
This is an old revision of the document!
Table of Contents
Pioneer 1 - Wired CbM Evaluation Platform
Overview
The Pioneer 1 - Wired CbM Evaluation Platform provides a robust industrial wired link solution for the ADcmXL3021 Triaxial Vibration Sensor en/products/adcmxl3021.html. The ADcmXL3021 features ultra low noise density (26 μg/√Hz) and wide bandwidth to 10 kHz, which supports excellent measurement resolution and tracking of key vibration signatures. The EV-CbM-Pioneer1-1Z and EV-CbM-Pioneer1-2Z kits provide a complete plug and play solution for operating the ADcmXL3021 on an RS-485 network over meters of cable in harsh industrial environments. This wired evaluation platform is enables monitoring of industrial assets to improve up-time, accelerating the path to Industry 4.0.
EV-CbM-Pioneer1-1Z / EV-CbM-Pioneer1-2Z Kit Features
- Provides 3 different Slave Board designs for ADcmXL3021 attach, which enable system design flexibility. Figure 1 and Table 1 provide details. Slaves 2 and 3 provide a direct SPI to RS-485 link, while Slave 1 includes an microcontroller which provides a UART to RS-485 interface.
- Combines power and data over 1 standard cable, which reduces cable and connector costs at remote Sensor nodes.
- Provides industry standard RJ45/RJ50 cables and connectors which are well shielded for noisy environments, are not bulky, and provide a path to IP67 enviornmental rating for integrated CbM module.
- Includes a Master interface board with multiple connectors for system controller attach.
- Dedicated software GUI enables simple configuration of the ADcmXL3021 device, and vibration data and capture over long cables.
Table 1. Solution Performance Trade Offs
SPI SCLK vs. Cable Length Recommendations
The following guidelines apply for the direct SPI to RS-485 link designs (DEMO-CbM-Slave2-Z and DEMO-CbM-Slave3-Z). The SPI to RS-485/RS-422 link designs include a SPI clock transfer over RS-422 (SCLK) and a power over data lines implementation (phantom power), where data and power share the same twisted pair (SPI MISO).
Cable Effects
- Over long cable runs the SPI SCLK signal will incur a propagation delay through the cable, of the order of 400-500 ns for a 100 m cable.
- For a SPI MOSI data transfer from Master to Slave, the MOSI and SCLK are equally delayed by the cable.
- However, data sent from the slave MISO to the master will be out of sync with SPI SCLK by twice the cable propagation delay.
Maximum SPI SCLK
- Is set by the system propagation delay, which includes cable propagation delay, and Master + Slave Component propagation delays.
Minimum SPI SCLK
- Is set by the Phantom Power filter components, which high-pass filter data on SPI MISO. This technique requires that the data signals being transmitted do not have content at DC or at very low frequencies. If operating at higher frequencies in the MHz range, it is important to note that a long string of logic '1' bits will mean a dynamic effective data rate in the kHz.
Typical Performance
- Typical SPI SCLK rate vs. cable length performance in a Phantom Power network is characterized in Figure 2. This shows DEMO-CbM-Slave3-Z (non-isolated slave) and DEMO-CbM-Slave2-Z (isolated slave)error free performance when porting the ADcmXL3021 SPI output over cabling.
Figure 2. SPI SCLK vs. Cable Length Typical Performance
Getting Started
Equipment
The following is supplied as part of the EV-CbM-Pioneer1-1Z demo kit:
- Master Interface Controller board DEMO-CbM-Master-Z.
- Low complexity non-isolated Slave Sensor interface board DEMO-CbM-Slave3-Z.
- Low complexity isolated Slave Sensor interface board DEMO-CbM-Slave2-Z.
- 2m RJ50 cable (194612-02) and 10m RJ50 cable (194612-10)
- AC/DC Power Supply - EU/UK/US/AU
The following is supplied as part of the EV-CbM-Pioneer1-2Z demo kit:
- All of the EV-CbM-Pioneer1-1Z demo kit contents
- Cypress SuperSpeed Explorer kit (CYUSB3KIT-003) and USB 3.0 cable.
The following equipment is suggested as a vibration source, but not strictly required, as the system can also be tested manually:
- Power supply for the cooling fan
Typical Setup
The following steps describe a typical setup, as shown in Figure 3, to communicate over a SPI to RS-485 link using either DEMO-CbM-Slave2-Z or DEMO-CbM-Slave3-Z:
- Ensure that the following jumper selections are made for the DEMO-CbM-Master-Z: LK8: position A or position B, and LK5 and LK6: Position A. The LK8 jumper needs to be set, but the position is at the user's discretion.
- Connect the supplied 2-meter RJ50 cable to the J10 RJ50 connector on the DEMO-CbM-Master-Z as indicated in Figure 4. Do not confuse this with the RJ45 connector (J1). Inserting RJ50 cable plugs into RJ45 connectors will damage the plug/connector contacts.
- Connect the Cypress Evaluation Board CYUSB3KIT-003 as shown in Figure 4 below. J6 and J7 on the DEMO-CbM-Master-Z align with the like-named J6 and J7 on the CYUSB3KIT-003.
- Connect the supplied 2-meter RJ50 cable to the J10 RJ50 connector on the DEMO-CbM-Slave3-Z (or DEMO-CbM-Slave2-Z).
- Connect the ADcmXL3021 XL module hi-rose connector (male) to the hi-rose connector (female) on the DEMO-CbM-Slave3-Z. Refer to Figure 5 for connector orientation. Ensure that Pin1 on both connectors is aligned as shown.
- Connect the Power Supply to the barrel connector on the DEMO-CbM-Master-Z. The power supply should be set to a minimum of +6 V and a maximum of +12 V. This provides power to both master and slave boards.
- Note: the Master board barrel connector is configured for a positive centre tip power supply. For the demo kit power supply –→ connect the positive centre (+) to the positive centre (+) on the small tip adaptors.
- Connect the USB 3.0 cable supplied with the CYUSB3KIT-003 to a USB 3.0 port on your computer.
Figure 3. Typical Evaluation Setup
Figure 5. Hi-Rose Connector Orientation and S2 Pushbutton Switch
Software Application (GUI)
Software Installation
Two downloads are required, with all software available on the ADcmXL3021 wiki.
- Download and unzip the file called FX3Driver.zip. Then run the DriverSetup.exe file
- Download, unzip, and Run the ADCMXL Evaluation Software, version 2.1.8.
GUI measurements using Typical Setup
- Open the Vibration Evaluation software version 2.1.8 on your computer.
- Open the ‘Comm’ menu and select ‘SPI’. Set the SPI SCLK to 2.5 MHz and hit ‘update’.
- Select Manual Time Capture (MTC) from the Mode Selection drop down menu, and hit the start button.
- For the Typical setup described in Figure 3 – the X, Y, and Z axis MTC measurements are shown in Figure 6.
- The corresponding Manual Fast Fourier Transform (MFFT) measurements are shown in Figure 7.
Figure 6. Typical Manual Time Capture Plot - corresponding to Figure 3 Typical Setup
Figure 7. Typical Manual FFT Plot - corresponding to Figure 3 Typical Setup
GUI measurements for a non-Repetitive Vibration Source
To provide a more easily visible Manual Time Capture (MTC) of a 'finger tap' vibration on the top surface of the ADcmXL3021, access the AVG_CNT register as shown in Figure 8. Write HEX 0x3 to AVG_CNT and perform a read back to confirm the write. This will decimate the signal so that the MTC waveform can be viewed easily. Figure 9 shows an example MTC measurement where a 'finger tap' vibration is applied to the top surface of the ADcmXL3021 module.
Figure 8. Write Hex 0x3 to the AVG_CNT Register to Decimate
Figure 9. Typical Manual Time Capture plot - Finger Tap Vibration Setup
Schematics, Layout, BOM
Schematics, layout, BOM, and Gerber file for the DEMO-CbM-Slave2-Z: click here to download
Schematics, layout, BOM, and Gerber file for the DEMO-CbM-Slave3-Z: click here to download
Schematics, layout, BOM, and Gerber file for the DEMO-CbM-Master-Z: click here to download
Schematics, layout, BOM, and Gerber file for the DEMO-CbM-Expandr-Z: click here to download
Change Log
*July 2019. Initial Release. *August 2019. Added additional information on demo power supply configuration.
- EVAL-AD5940评估套件用户指南 9次下载
- CN0412用户指南维基
- UG-025:评估板用户指南
- MIC45404评估板用户指南 18次下载
- MIC2128评估板用户指南 12次下载
- PAC1934评估板用户指南 5次下载
- ADP5050评估板用户指南
- EDK套件:SnapSensor评估演示用户指南
- MCP16502评估板用户指南 16次下载
- MCP9600基础知识及评估板用户指南
- MCP3903评估板用户指南
- Si8281评估板用户指南 0次下载
- Si8284评估板用户指南 0次下载
- 一种新的煤层气产出动态预测模型
- 英国煤和煤层气资源及规划
- 什么是云平台?软件被云平台拦截了怎么办 1734次阅读
- 研究石墨烯气凝胶基双层相变复合材料用于自适应个人热管理 805次阅读
- 未来服务对传感器的需求:用于状态监测的智能传感器 754次阅读
- 工业设备运维云平台的设计与实现 1600次阅读
- CPK-RA6M4评估板入门指南(六) 2169次阅读
- CPK-RA6M4评估板入门指南(五) 2256次阅读
- CPK-RA6M4评估板入门指南(四) 1236次阅读
- CPK-RA6M4评估板入门指南(一) 1355次阅读
- 维基链的命令行是如何高效快速的对维基链节点进行操作的 964次阅读
- 工业互联网平台核心技术之运维技术 6220次阅读
- 基于SOPC和ZigBee的三维移动天线平台设计浅析 840次阅读
- 由浅入深的对其降维原理进行了详细总结 8037次阅读
- 累积式气体流量计的原理及设计 2343次阅读
- 系统演示平台便于快速进行原型制作与评估 1504次阅读
- 有线宽带与传统ADSL的区别 1250次阅读
下载排行
本周
- 1电子电路原理第七版PDF电子教材免费下载
- 0.00 MB | 1491次下载 | 免费
- 2单片机典型实例介绍
- 18.19 MB | 95次下载 | 1 积分
- 3S7-200PLC编程实例详细资料
- 1.17 MB | 27次下载 | 1 积分
- 4笔记本电脑主板的元件识别和讲解说明
- 4.28 MB | 18次下载 | 4 积分
- 5开关电源原理及各功能电路详解
- 0.38 MB | 11次下载 | 免费
- 6100W短波放大电路图
- 0.05 MB | 4次下载 | 3 积分
- 7基于单片机和 SG3525的程控开关电源设计
- 0.23 MB | 4次下载 | 免费
- 8基于AT89C2051/4051单片机编程器的实验
- 0.11 MB | 4次下载 | 免费
本月
- 1OrCAD10.5下载OrCAD10.5中文版软件
- 0.00 MB | 234313次下载 | 免费
- 2PADS 9.0 2009最新版 -下载
- 0.00 MB | 66304次下载 | 免费
- 3protel99下载protel99软件下载(中文版)
- 0.00 MB | 51209次下载 | 免费
- 4LabView 8.0 专业版下载 (3CD完整版)
- 0.00 MB | 51043次下载 | 免费
- 5555集成电路应用800例(新编版)
- 0.00 MB | 33562次下载 | 免费
- 6接口电路图大全
- 未知 | 30320次下载 | 免费
- 7Multisim 10下载Multisim 10 中文版
- 0.00 MB | 28588次下载 | 免费
- 8开关电源设计实例指南
- 未知 | 21539次下载 | 免费
总榜
- 1matlab软件下载入口
- 未知 | 935053次下载 | 免费
- 2protel99se软件下载(可英文版转中文版)
- 78.1 MB | 537793次下载 | 免费
- 3MATLAB 7.1 下载 (含软件介绍)
- 未知 | 420026次下载 | 免费
- 4OrCAD10.5下载OrCAD10.5中文版软件
- 0.00 MB | 234313次下载 | 免费
- 5Altium DXP2002下载入口
- 未知 | 233046次下载 | 免费
- 6电路仿真软件multisim 10.0免费下载
- 340992 | 191183次下载 | 免费
- 7十天学会AVR单片机与C语言视频教程 下载
- 158M | 183277次下载 | 免费
- 8proe5.0野火版下载(中文版免费下载)
- 未知 | 138039次下载 | 免费
评论
查看更多